[vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1590487573426{margin-top: 0px !important;border-top-width: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1588844614850{margin-top: 0px !important;margin-bottom: 0px !important;border-top-width: 0px !important;border-bottom-width: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}”][vc_column_text css=”.vc_custom_1593769485857{margin-top: 7px !important;margin-bottom: 7px !important;border-top-width: 7px !important;border-bottom-width: 7px !important;padding-top: 7px !important;padding-bottom: 7px !important;padding-left: 45px !important;}”]HOMEPAGE > WAGO PRODUCTS > CURRENT TRANSFORMERS
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content_no_spaces” equal_height=”yes” css=”.vc_custom_1590487593992{margin-top: 0px !important;margin-bottom: 0px !important;border-top-width: 0px !important;border-bottom-width: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1590487516639{margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 30px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 30px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 30px !important;}”][vc_column_text css=”.vc_custom_1593771495423{padding-top: 30px !important;padding-left: 70px !important;}”]
CURRENT TRANSFORMERS AND VOLTAGE TAPS
Anywhere high currents are measured and processed, WAGO’s current transformers are your first choice. Voltage taps also easily and safely tap the measurement voltage in existing systems.
Your benefits:
- Safe, secure wiring with CAGE CLAMP® Connection Technology
- Full range of products for new systems, as well as for retrofitting existing installations
- Coordinated components for your energy data management
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”3291″ img_size=”full” css=”.vc_custom_1593769667679{padding-left: 50px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268089360{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589438218560{margin-right: 0px !important;margin-bottom: 10px !important;margin-left: 0px !important;border-top-width: 30px !important;border-right-width: 0px !important;border-bottom-width: 10px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 0px !important;padding-bottom: 10px !important;padding-left: 0px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589355493649{margin-right: 30px !important;margin-left: 0px !important;border-right-width: 30px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3293″ img_size=”full” css=”.vc_custom_1593770671763{margin-right: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589355523739{margin-right: 30px !important;margin-left: 0px !important;border-right-width: 30px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593770951772{margin-right: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Rogowski Coils
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268089360{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589545953999{margin-top: 30px !important;margin-bottom: 30px !important;border-top-width: 30px !important;border-bottom-width: 30px !important;padding-top: 30px !important;padding-bottom: 30px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589181719414{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3294″ img_size=”full” css=”.vc_custom_1593771003407{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589181733143{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593771461612{margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Plug-In Current Transformers with picoMAX® Connection Technology
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268089360{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589268106728{margin-top: 30px !important;margin-bottom: 30px !important;border-top-width: 30px !important;border-bottom-width: 30px !important;padding-top: 30px !important;padding-bottom: 30px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589181745122{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3295″ img_size=”full” css=”.vc_custom_1593771120400{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589181758748{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593771449525{margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Split-Core Current Transformers
Advantages:
- Compact split-core current transformers – ideal for retrofitting existing systems
- No current path interruption
- Easy and cost-effective installation via cable ties
- Transformer leg (855-5xxx) can be completely removed if space is tight
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268125562{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589268188059{margin-top: 30px !important;margin-bottom: 30px !important;border-top-width: 30px !important;border-bottom-width: 30px !important;padding-top: 30px !important;padding-bottom: 30px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589181771260{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3296″ img_size=”full” css=”.vc_custom_1593771207729{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589181781852{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593771436888{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Plug-In Current Transformers with CAGE CLAMP® Connection Technology
Advantages:
- Screwless CAGE CLAMP® Connection Technology
- Quick-mount kit for easy and cost-effective installation
- Tremendous versatility thanks to several mounting options
- Easy transformer short-circuiting via redundant secondary terminals S1 and S2
- UL listed
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268218318{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589268235498{margin-top: 30px !important;margin-bottom: 30px !important;border-top-width: 30px !important;border-bottom-width: 30px !important;padding-top: 30px !important;padding-bottom: 30px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589181771260{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3297″ img_size=”full” css=”.vc_custom_1593771301155{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589181781852{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593771388107{margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Voltage Taps for Insulated Conductors
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” content_placement=”middle” css=”.vc_custom_1589268218318{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;background-color: #d9d9d9 !important;}”][vc_column css=”.vc_custom_1589191584489{margin-top: 10px !important;margin-bottom: 10px !important;border-top-width: 10px !important;border-bottom-width: 10px !important;padding-top: 10px !important;padding-bottom: 10px !important;}”][/vc_column][/vc_row][vc_row full_width=”stretch_row_content” equal_height=”yes” css=”.vc_custom_1589268235498{margin-top: 30px !important;margin-bottom: 30px !important;border-top-width: 30px !important;border-bottom-width: 30px !important;padding-top: 30px !important;padding-bottom: 30px !important;}”][vc_column width=”1/2″ css=”.vc_custom_1589181771260{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_single_image image=”3298″ img_size=”full” css=”.vc_custom_1593771550268{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1589181781852{margin-top: 0px !important;margin-right: 30px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-top-width: 0px !important;border-right-width: 30px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 0px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”][vc_column_text css=”.vc_custom_1593771616065{margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;border-right-width: 0px !important;border-bottom-width: 0px !important;border-left-width: 0px !important;padding-top: 30px !important;padding-right: 30px !important;padding-bottom: 0px !important;padding-left: 0px !important;}”]
Current and Voltage Tap
A combination of current transformer and voltage tap, WAGO’s current and voltage tap can be quickly and easily mounted into the jumper slot of the 95 mm2 (4/0 AWG) high-current through terminal block (285-195).
Advantages:
- Power data can be directly tapped into the power supply
- Integrated 250 A/1 A current transformer
- Complies with accuracy class 0.5 per EN 61869-2 for exact measurement results
- Fused voltage path protects downstream measurement devices
[/vc_column_text][/vc_column][/vc_row]